DataNet 고성능 무선 데이터로거 ZigBee
    · 고객선호도 :
    · 판매가격 : 전화문의

회원가입을 하시면 할인된가격을 보실수 있습니다.
모든가격은부가세별도 입니다.
회원이 되시면 가격변동정보, 신제품, 특판제품, 기술정보등 다양한
뉴스정보를 보내드립니다.
30만원미만은 택배비 3,000원(착불)입니다.
카드결재시 세금계산서 발행 불가합니다.
배송은 평균 2~3일정도 예상됩니다.
                    (0)                     (0)                     (0)




Click to enlarge
http://www.fourtec.com/product/datanet
사양 및 카다로그

DataNet

High-End Wireless Data Acquisition System

DataNet hardware and software solution empowers any organization to control distributed networks from a single location. Using Zigbee wireless mesh network configuration, allowing for 65,000 units in each network, DataNet enables real-time monitoring of multiple test points in a single operation.

  • Reliable bi-directional transmission ensuring
    no data loss
  • Transmission range can be constantly expanded by adding additional network units
  • Minimal costs thanks to wire-free infrastructure
  • Portable units facilitating easy deployment in various environments
  • Receivers, recognizing up to 8 end units and 16 Repeaters
  • Repeaters, recognizing up to 24 end units and 16 Repeaters (simultaneously).
 

DataNet System contains:

    
DNL910 and DNL920 DNL910 and DNL920
Internal temperature and/or humidity loggers.
Supports four external inputs: 4 to 20 mA, 0 to 1 V, 0 to 50 mV, PT-100 2 wires, Thermocouples (J, K and T), Dry Contact, Pulse Counter and Frequency.
Rechargeable battery operation.

DNL910 PA and DNL920 PA DNL910 PA and DNL920 PA
Loggers with integrated power amplifier for extended range. Same supported external and internal sensors as DNL910 and DNL920.

DNR900 Receiver/Repeater DNR900 Receiver/Repeater
The heart of the system controls and collects the data from the end units. Also suitable for extending the system range.

Mini DataNet Mini DataNet Models
Cost-effective wireless single and dual channel loggers, battery operated only
DNL804 (External 4 to 20 mA)
DNL808 (External NTC 10KΩ)
DNL810 (Internal Temp/RH).

DNR800 Mini Repeater DNR800 Mini Repeater
For extending the system range.

 





DataNet
High-End Wireless Data Acquisition System

Mini DataNet

Mini DataNet Data Logger

The DataNet is a 16-bit data logging system with 4 inputs for direct measurement and recording of PT-100, thermocouple (J, K, T), voltage, current, frequency, pulse and dry contact. Data transmission from units to the central computer utilizes the brand new ZigBee wireless telemetry protocol.

ZigBee wireless protocol uses a 2.4 GHz license free frequency RF band. Each DataNet unit also serves as a transmission repeater to neighboring units, forming a reliable mesh network of up to 65,000 nodes. The ZigBee key features include:

  • Reliable transmission ensuring no data loss
  • Transmission range that can be constantly expanded by adding additional nodes
  • Minimal costs thanks to wire-free infrastructure
  • Portable units facilitating easy deployment in various environments
     

  Click here to take the DataNet Product Tour 


DataNet Diagram

Click to enlarge

- Click image to enlarge -
 

 

Key DataNet Benefits:

  • Wireless data logging
  • Internal RH/Temp sensors
  • 4 recording inputs: 4-20 mA, 0-1 V, Pulse counter, PT-100 2-wires, Thermocouple J, K and T and dry contact
  • Fully reliable monitoring network
  • Cost effective system
  • Multiple alarms including SMS and e-mail to any location
  • Long range monitoring
  • Up to 65,000 network units
  • License-free RF band worldwide
  • Operating keypad and large LCD display

Specifications

Click here to view DataNet Specifications (PDF Format)

Brochure

Click here to view DataNet Brochure (PDF Format)

DataNet 
Software  

DataNet

DataNet software provides security for your products with online monitoring and control.

  • Graphical analysis Windows® based software
     
  • Fast data download
     
  • Data display in numeric or graphical forms
     
  • On-line retrieval and display of data in real-time
     
  • Setup wizard
     
  • Automatic definition of new sensors
     
  • Ability to read defined sensor units on the LCD display
     
  • Full calibration of DataNet via software
     
  • Documentation and filing
     
  • Alarm levels on graphs
     
  • Export and import to and from spreadsheets
     
  • Analytical functions for collected data
     
  • Manual backup of DataNet calibration settings
     
  • Over-the-air firmware updates
     

System Requirements

Software

Compatible with Windows 2000 SP3, Windows 2003, Windows XP SP2, Windows Vista. Internet Explorer 5.01 or later is required

Hardware

  • Pentium 800 MHz or higher
  • 256 MB RAM
  • 250 MB available disk space



    DataNet 
    Sensors  

    The DataNet data loggers support the following sensor inputs:

    4 to 20 mA

    Range: 4 to 20 mA
    Resolution: 4.76 µA
    Accuracy: ±0.5%
    Loop impedance: 21 Ω
    Maximum load: 30 mA, 5.2 V

    0 to 50 mV
    Range: 0 to 50 mV
    Resolution: 3 µV
    Accuracy: ±0.5%
    Input impedance: 25 MΩ
    Maximum voltage: 5.2 V

    0 to 1 V
    Range: 0 to 1 V
    Resolution: 200 µV
    Accuracy: ±0.5%
    Input impedance: 25 MΩ
    Maximum voltage: 5.2 V

    Temperature PT-100 (2 wires) *
    Range: -200 to 400 ºC
    Resolution: 0.1 ºC (7 mΩ)
    Accuracy:
       -200 to 60 ºC ±0.5%
        60 to 400 ºC ±0.5%
       -60 to 60 ºC ±0.3 ºC

    Temperature Thermocouple J
    Range: -200 to 1,000 ºC
    Resolution: 0.1 ºC (1µV)
    Accuracy:
       -200 to -60 ºC ±0.5%
        60 to 1,000 ºC ±0.5%
       -60 to 60 ºC ±0.5 ºC
    Cold junction compensation: ±0.3 ºC

    Temperature Thermocouple K
    Range: -250 to 1,000 ºC
    Resolution: 0.1ºC (1 µV)
    Accuracy:
       -250 to -60 ºC ±0.5%
        60 to 1,000 ºC ±0.5%
       -60 to 60 ºC ±0.5 ºC
    Cold junction compensation: ±0.3 ºC

    Temperature Thermocouple T
    Range: -200 to 400 ºC
    Resolution: 0.1ºC (1 µV)
    Accuracy:
       -200 to -60 ºC ±0.5%
        60 to 400 ºC ±0.5%
       -60 to 60 ºC ±0.5 ºC
    Cold junction compensation ±0.3 ºC

    Pulse Counter (Input 4 only)
    Zero crossing detector
    Range: 1 to 65,536 counts
    Resolution: 1 count
    Frequency range: 0 to 4,000 KHz
    Input signal: 0 to 5 V
    Input impedance: 470 Ω

    Frequency (Input 4 only)
    Zero crossing detector
    Range: 20 Hz to 4 KHz
    Input signal: 0 to 4000 Hz
    Input impedance: 470 Ω

    Dry Contact
    Range: Open/Closed

    Internal Temperature (Logger model: DNL 910)
    Type: PT-100
    Range: -20 to 50 ºC
    Resolution: 0.1 ºC (1µV)
    Accuracy: ±0.3 °C

    Internal Temperature (Logger model: DNL 920)
    Type: Digital
    Range: -20 to 50 ºC
    Resolution: 0.1 ºC (1µV)
    Accuracy: ±0.5 °C

    Internal Humidity (Logger model: DNL 920)
    Range: 5 to 95 %
    Resolution: 0.5%
    Accuracy (in software): 3% at 5 to 95%, 5% at 5 to 10% and 90 to 95% 

    * PT-100 External Sensor also available from Fourier Systems
    Range: -70 to 400 ºC
    Teflon cable length: 2.5, 4 or 6 meters
    Teflon cable range: -65 to 200 ºC
    Probe diameter: 6 mm
    Probe length: 81 mm

번호 제목 작성자 작성일 평가점수
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다.
 
* 이 상품을 사용해 보셨다면 사용후기를 써 주십시오.
번호 제목 작성자 작성일 답변
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오.
 
* 이 상품에 대한 궁금한 사항이 있으신 분은 질문해 주십시오.
이 상품과 관련된 상품이 없습니다.
 
회사소개 | 서비스이용약관 | 개인정보취급방침
경기도 성남시 중원구 상대원동 513-15번지 선텍시티B/D 708호
대표 전화 : 031-777-1588 / 팩스 : 031-777-1587 / 개인정보관리책임자 : 관리자
사업자 등록번호 : 116-81-31753 / 통신판매업신고 성남시 제2005-886호
대표 : 홍영화 / 운영자 : 윤상미
Copyright ⓒ 2002 상호 : (주)코린스. All Rights Reserved.
가입사실확인