ÀÚµ¿·Î±×ÀÎ
 

  ¿À´Ã : 1,529¸í 
  ¾îÁ¦ : 1,809¸í 
  ±×Á¦ : 1,912¸í 
  ÃÖ´ë : 7,056¸í 
  Àüü : 5,799,039¸í 
ÇöÀçÀ§Ä¡ : Home > µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è > Àڱ⠾з±â·Ï°è

 
PR140- °í¿Â.¾Ð·Â µ¥ÀÌÅͷΰÅ
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ÆÇ¸Å°¡°Ý : ÀüÈ­¹®ÀÇ

¡á
ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á
¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á
Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
http://mail.naver.com/readReceipt/notify/?img=qwR0M6%2BnMB0CpxpSFqmspAtqKzEZaxJ4KxbqFxC4KAKrKrM9FobmpoIg%2BH%2B0Mogq74lR74lcWNFlbX30WLloWrdQarJqtzRTb405bZloWZlOb2%3D%3D.gif
http://mail.naver.com/readReceipt/notify/?img=qwR0M6%2BnMB0CpxpSFqmspAtqKzEZaxJ4KxbqFxC4KAKrKrM9FobmpoIg%2BH%2B0Mogq74lR74lcWNFlbX30WLloWrdQarJqtzRTb405bZloWZlOb2%3D%3D.gif

ºê·Î¼Å
 

Features

  • Operates up to 140¡ÆC
  • Pressure logging range: 0 to 5 Bar (0-72.5 PSIA)
  • Submersible (IP68)
  • N.I.S.T. Traceable
  • User Replaceable Battery
  • Rugged
  • Programmable Start Time
  • Engraved Label
  • CE Compliant
  • Software Battery Life Indicator

The MadgeTech PR140 High Temperature Pressure Data Logger is designed for use in autoclave validation and mapping. This rugged device can withstand temperatures up to 140¡ÆC and is completely submersible (IP68).

The PR140 is built with a precision stainless steel pressure gauge. The device has an accuracy of ¡¾0.03 Bar (¡¾0.435 PSI), which can be achieved over a wide temperature range, from –20¡ÆC to +140¡ÆC (-4¡ÆF to 284¡ÆF). The PR140 can be programmed to take readings as often as once per second (1Hz), and has non-volatile memory that can store up to 32,700 measurements.

The PR140 is easy to use. Simply place it in the IFC400 docking station, connect to a computer, and the device can be started, stopped or downloaded using the MadgeTech software. Graphical, tabular and summary data is provided for analysis and can be viewed in PSIA, mmHg, bar, Torr and kPa. The data can also be automatically exported to Excel¢ç for further calculations.

Applications for the PR140 high-temperature pressure data logger include:
  • Autoclave Validation and Mapping
  • Canning and Cooking Pouches
  • Pressurized Process Reactors and Streams
  • Beverage Production, Including Wine and Soda
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§
°æ±âµµ ¼º³²½Ã Áß¿ø±¸ »ó´ë¿øµ¿ 513-15¹øÁö ¼±ÅØ½ÃÆ¼B/D 708È£
´ëÇ¥ ÀüÈ­ : 031-777-1588 / ÆÑ½º : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆÇ¸Å¾÷½Å°í ¼º³²½Ã Á¦2005-886È£
´ëÇ¥ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
Copyright ¨Ï 2002 »óÈ£ : (ÁÖ)ÄÚ¸°½º. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ